Urologist, J. Francois Eid, M.D., Lauds Improvements In Penile Prosthesis And Artificial Urinary Sphincter Technologies

Dr. J. Francois Eid has performed more internal penile implant surgeries than anyone in the world and has built a reputation for excellence in the treatment of erectile dysfunction (ED). After examining the latest generation of Inflatable Penile Prosthesis (IPP) and Artificial Urinary Sphincter (AUS) technologies from American Medical Systems (AMS) and Coloplast Corporation, reviewing pertinent studies, and drawing on his 20 years of experience performing penile prosthesis surgery and overseeing his patients' recuperation and subsequent training in operating the devices, Dr. Eid has high praise for the recent improvements. Updates have been made to the IPP pumps offered by both AMS and Coloplast, as well as to the CX and LGX cylinders offered by AMS. Also, AMS has added an antibiotic coating to its AUS.

Momentary Squeeze (MS) Pump - AMS

AMS's Momentary Squeeze (MS) Pump was first introduced nearly two years ago, and Dr. Eid has implanted it with great success in patients suited to the CX-cylinder and LGX-cylinder versions. (The LGX model offers the potential for increased penile length in patients complaining of penile shortening after radical prostatectomy.) Both cylinders now feature redesigned proximal ends. At only 9.5mm in diameter, the ends allow for significantly easier insertion for patients with fibrotic proximal corporal bodies.

The MS Pump's advantages include a smaller profile (which enables a more discreet placement) and one-touch deflation. However, this quality can result in operational difficulties with inflation (more difficult to get a hold of within the scrotum) and deflation (small button can initially be difficult to find). In addition, its new lockout valve has the advantage of preventing auto-inflation (potentially embarrassing and/or painful), but can at times make it difficult to initiate inflation. For these reasons, Dr. Eid recommends this pump for the younger patient with an average-sized penis.

Tactile Pump (700 CX Series) - AMS

"The AMS 700 CX Series with the Tactile Pump remains my prosthesis of choice for the older patient where pump concealment is not an issue," says Dr. Eid. "This pump is large, easily palpable, remains the softest to inflate and has a very large deflation footprint, which is quickly recognized by the patient." The Tactile pump is not available with the LGX cylinders.

Titan Pump - Coloplast

The FDA approved the improvements to the pump component of the Coloplast Titan prosthesis in July 2008. Although the cylinders and reservoir remain the same as the previous model, the pump now features a one-touch-release (OTR) deflation valve -- easy for patients to locate and operable with one hand. In addition, the pump offers a non-bulky, low-profile size; enhanced silicone for higher threshold "tear strength" (likely to result in increased product durability, an issue with previous versions); and an overall simplicity likely to decrease repeat office visits, phone calls, and repeat training time. From a hospital standpoint, intraoperative prep of the device provides for easier priming of the implant system (the removal of excess air prior to filling) and may reduce slightly the overall intraoperative time.

"This remains a great device for the patient with a larger penis," says Dr. Eid, "as these are the only cylinders that will expand to 22mm girth." In addition, only Titan cylinders are available in lengths of 24cm, 26cm and 28cm.

Although the pump is easily identified and operated by patients, the small size of the deflation valve sometimes requires a longer learning curve.

In a recent study ("Evaluation of Three Penile Prosthesis Pump Designs in a Blinded Survey of Practitioners," Urologic Nursing, 2008), 32 medical professionals, all familiar in teaching the operation of penile implants to patients, reviewed currently available penile pumps. The blindfolded reviewers, examining the pumps under time constraints through mock scrotal sacs, were asked to rate device:

-- ease of location of deflation valve
-- ease of inflation
-- ease of deflation, and
-- anticipated ability to train patients in clinical setting.

The Titan OTR pump design performed very well and "consistently demonstrated a significant advantage in subject preference." (Quallich, Ohl & Dunn, 2008, p. 5).

Artificial Urinary Sphincter - AMS

AMS has improved the AUS by coating the device surface with inhibizone. This is the same antibiotic coating (Rifampin and Minocin) currently available on the IPP that has dramatically reduced infection rates since its introduction in 2001. In combination with Dr. Eid's self-developed "no-touch" surgical technique, which eliminates direct and indirect contact between the prosthesis and the patient's skin (the origin of most infections), he believes the new coating will offer additional protection against the most common pathogens responsible for sphincter infections.

Dedicated to Patient Education

Dr. Eid has developed a website http://www.urologicalcare.com dispelling common misconceptions about penile implant surgery. Having performed over 3,000 penile implant surgeries (the most worldwide), Dr. Eid knows what a remarkable and positive difference the treatment can make in a man's life. Between retaining a normal penis look and feel, employment of multiple techniques for preventing infection, and steady diminishment of pain until it is completely gone within 2-4 weeks, penile implant surgery has proven to be an effective treatment for many men, resulting in normal, healthy and productive lives.

About J. Francois Eid, M.D, and urologicalcare.com

Dr. Eid is the director and founder of Advanced Urological Care in New York City. He is also a Clinical Associate Professor of Urology at Cornell University. Dr. Eid is one of the foremost specialists in urological prosthetic reconstruction and performs over 300 internal penile implants per year. Dr. Eid leads workshops on penile prosthesis surgeries worldwide. More information about Dr. Eid and his expertise with erectile dysfunction treatment, penile prosthesis implantations and artificial urinary sphincters can be found on his website,